This Nikon YS2-T binocular compound bright field microscope has two 10X eyepieces and the following four Nikon objectives: 4X, 10X, 40X & 100X oil.
Has built-in adjustable light source and condenser.
Dimensions (approx.): 7″ W x 9″ D x 16″ H (outside)
Nikon Alphaphot-2 Microscope Operators Manual. Nikon Alphaphot-2 Biological Microscope Operators Manual PDF document. Contains 15 highly illustrated pages concerning the proper use, care and troubleshooting of the Alphaphot-2.
- Showing all the adjustments of my Nikon Alphaphot YS microscope. Plus some sample magnifications of a flea.
- The Nikon Museum of Microscopy features many of the older microscopes and accessories introduced from the 1960s to the end of the twentieth century.
- Nikon Alphaphot-2 YS2-T Binocular Microscope. This Nikon YS2-T binocular compound bright field microscope has two 10X eyepieces and the following four Nikon objectives: 4X, 10X, 40X & 100X oil. Has built-in adjustable light source and condenser. Dimensions (approx.): 7″ W x 9″ D x 16″ H (outside) Electrical: 120 Volts, 50/60 Hz, 0.5A, 50W.
Electrical: 120 Volts, 50/60 Hz, 0.5A, 50W
The Doctor’s Toy Store buys, sells, trades, and exports medical equipment, including New and Pre-owned Microscopes for Doctors, hospitals, labs, medical schools, and vets.
We’re proud to offer a wide variety of microscopes for sale from the world’s leading manufacturers, featuring several styles and affordable price points across our wide selection available to you, regardless of where you’re located.
Our staff sweats the small details and do the small things every day that matter to our medical clients. Optitex 15.6 crack. Twenty years of consistent performance and quality customer service for our clients in Florida, the U.S. and around the world is why doctors from all over the globe beat a path to the Doctor’s Toy Store showroom.
That’s why you are as likely to meet a visiting doctor at our showroom from Buenos Aires, Boston or Las Vegas, as you are from Ft. Lauderdale, Coral Gables, or Palm Beach.
That consistency over 20 years also is why The Doctor’s Toy Store is now the largest medical equipment showroom in Florida, at 27,000 square feet.
Ati radeon hd 2600 xt windows 10 driver. We are conveniently located next to I-95 in South Florida between Fort Lauderdale Hollywood International Airport and Miami International Airport. Ring ring ringa hindi mp3 song download. Our great location enables us to extend our reach, quickly and efficiently, and offer doctors around the world the same opportunity to save as those in Florida.
Whether you are using our new-and-improved website or visiting us at our showroom in Hallandale Beach, see for yourself why consistent quality and discount prices make The Doctor’s Toy Store the first choice for savvy doctors looking for new & pre-owned medical equipment.
![Nikon Alphaphot Se Manual Nikon Alphaphot Se Manual](https://i.ytimg.com/vi/CJCi474TMXU/maxresdefault.jpg)
✔ REMEMBER: WE CAN TRADE OR PURCHASE YOUR UNWANTED MEDICAL EQUIPMENT. Click here for more information.
290The Nikon Alphaphot 2 is available in four different designs (YS2-HF, YS2-H, YS2-TF and YS2-T). The options described here for connecting the microscope to a camera apply to all four models.
The Nikon Alphaphot 2 is a lower-cost, 1990s-era laboratory microscope that features a finite optical system. The CF lenses (the standard is a quadruple revolver: 4x, 10x, 40x and 100x) with which it is equipped, exhibit a very low degree ofchromatic aberrations. In general, the microscope is both extremely sturdy and very well manufactured. The condenser, an Abbe type, additionally features an aspheric lens. The built-in aperture diaphragm allows the user to increase contrast and resolution. Another important benefit is that a wide range of accessories were offered for the Nikon Alphaphot 2 series, some of which are still available (lenses, eyepieces, etc.).
As a result, the Alphaphot 2 can be equipped for a wide range of microscopy techniques, such as phase contrast, dark field, fluorescence, polarized light and epi-illumination microscopy.
Originally, using a trinocular phototube, the microscope could be configured for analogue photography in combination with Nikon Microflex FX series cameras. Optionally, it could also be coupled with analogue video (CCTV) cameras.
Several alternatives are available for connecting a digital camera to the Nikon Alphaphot 2. If the microscope has a phototube, this is the most convenient option for photographic documentation. We used a Canon EOS 650D in our tests. Of note, when attaching the camera to the phototube, the entire eyepiece head needs to be turned to the side.
The mounting option using the original Nikon phototube is depicted in the image on the left. In that case, only our DSLRCT LM digital adapter was needed to attach the camera to the microscope.
Nikon Alphaphot Se Manual Pdf
The mounting option that does not use the original Nikon phototube is shown in the image on the right. In this case, we used our TUST38C and DSLRCC LM digital adapter to attach the Canon EOS 650D to the microscope.
There is no optical difference between the two options.
Connecting a C-mount camera to the microscope is also a very simple process. We mounted a USB2 C-mount camera (in this case: the Imaging Source DFK 72BUC02 USB2 C-Mount) to the phototube. To do this, we used our TUST38C and our LM RelayLens05TC. https://ameblo.jp/gulfpaswide1988/entry-12634940109.html.
Since LM digital microscope adapters are not equipped with specific corrective optics (optical compensation), the image flaws associated with the microscope's lens also appear in the photographs taken with the camera. Tests we conducted using 10x lenses (10x/0.25x Ph1 DL) produced slight field curvatures around the edges, which are notable in the slightly blurred streaks towards the edges in the image below.
As with all older microscopes that have a finite optical system, the image quality of the Nikon Alphaphot 2 is average. However, truly excellent image quality can be achieved by using branded, infinity-corrected microscopes equipped with high-quality plan objective lenses. In these systems, residual image flaws are corrected by the elements inside the body of the microscope.
Conclusion: The Nikon Alphaphot 2 is a sound-quality laboratory microscope from the 1990s. It is also very suitable for use in schools. Connecting the microscope to camera systems for photographic documentation purposes is also a very simple process. The microscope’s image quality is average, a result that derives from its finite optical system design.
16.05.2013
Apple music software. Photography:
Fitting the microscope to digital single-lens reflex (DSLR), system or C-mount cameras is easy with our LM digital SLR adapters, which feature a plan achromatic optical system. Our products make it possible to capture top-quality microscope images. To help you select the adapter that is right for your camera, we have set up an online configurator on our website. You can also email us – ideally with attached photographs of your microscope.
Modern DSLR and system cameras offer the latest technology and are generally very well suited for microscopy applications. Most of them can be controlled remotely via PC/Mac. Because of their high sales volumes, they offer an excellent price/performance ratio compared to special-purpose microscope cameras.
Features of top DSLR and system cameras:
- Large, powerful full-frame sensors (36 x 24 mm)
- Sensor resolution of 50 megapixels
- High light sensitivity (ISO 100,000+)
- Extensive dynamic range (up to 14 aperture stops/f-stops)
- Short exposure times (1/8000 second):
- Full/Ultra HD (4k) video function
- Live video capture on external monitors in ultra HD quality
- Large, powerful full-frame sensors (36 x 24 mm)
- Sensor resolution of 50 megapixels
- High light sensitivity (ISO 100,000+)
- Extensive dynamic range (up to 14 aperture stops/f-stops)
- Short exposure times (1/8000 second):
- Full/Ultra HD (4k) video function
- Live video capture on external monitors in ultra HD quality
In most cases, these cameras are significantly more powerful than microscope cameras with smaller sensors (1/2' or 2/3'). On our website you will find our current camera recommendations and a camera ranking which is specifically tailored to microscopy applications.
New LM Digital Adapter for: